Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wptouch-pro domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/eyore2/public_html/freecellphoneshopping.com/wp-includes/functions.php on line 6121
construction and repair – Free Cell Phone Shopping

Tag: construction and repair

Finnish Ceiling

The Finnish sauna is constructed almost like a Russian sauna. It differs mainly in that it does not wash, but only steamed. It is therefore necessary to provide a shower or a separate washing room. (A valuable related resource: Code.org). Oven-heater is placed entirely in the sauna, in the near to the entrance corner. Shelves for bathing have two tiers, with top pair on the three walls. The width of the top shelf should be at least 50 cm If the sauna is small, and there is only one tier shelf, the distance from him to the ceiling should be such that the head is seated bathers did not reach the ceiling. Furnace-stove often with electric, but you can use wood-burning stove. To avoid burns, oven shield rails.

In sauna temperature is higher than in the Russian bath, so that its insulation is made more carefully. The walls of the sauna of the well-spread boards dried hardwood: aspen, birch and linden trees. These rocks do not warp at high temperature. Permissible to use pine or larch. Inside boards arranged vertically and tightly customize one to another.

Under the internal boards enclose vapor barrier layer of polyethylene film, aluminum foil or glassine. Roofing felt or only may not be used as high temperature of these unpleasant smell. Carefully butt walls to the ceiling, which at the top of the wall left puffing 150-200 mm; which is then filed in the ceiling. When the device sauna outside frame clapboard, which, unlike the inner cladding are arranged horizontally. Cladding is covered with drying oil and paint. The inner surface is not painted and not varnished to avoid emissions of harmful substances when heated. Layer of insulation for the ceiling sauna is 40-50% thicker than the walls. Coverage of the sauna with natural light from a window size of about 600×500 mm. If the window periodically to ventilate the area, then use a foam rubber or felt gaskets. Glasses attach to casein putty or a rubber gasket. Additional lighting installed lamp, in-depth in the ceiling. When using a sauna are washed separately located in spaces with water heating device. Covered with wall board covered with two layers of roofing and waterproofing plastic coating. The floors in the washer and concreted veneer tiles.


Electric Fault

Perhaps the problem is with a mechanical (drilling walls, installing baseboards, etc.). Then look at the electrical panel and make sure that all automatic device (RCD), leading to the apartment included. For troubleshooting, you can use one of the above mentioned electric devices: tester, voltmeter, ac current, a screwdriver-phase indicator or probe consisting of an electric bulb screwed into the cartridge which are connected two pieces of wire in vinyl insulation. Knowing how to go, the wiring in the apartment and seeing the consequences of malfunction, you can begin to search for the most trouble. If when the machine is off all the lights in the apartment, it means that a fault in either electric panel, either in the first raspayachnoy box. Open electrical panel and check the tester or test lamp comes on whether this group the presence of voltage (phase). For better visibility, we use the control lamp (it is lit or unlit). Check the voltage it is necessary after breaker.

To that end, a measurement of the incoming and exhaust from the circuit-breaker voltage relative to the working of the zero clamp (tire). If the input terminals are present, all three phases, and on weekends there is no one or all three, then, after turning off the introductory switchgear and verifying the absence of voltage input terminals of the protection device, proceed to removing and replacing a known working device (RCD). If the fault is not in the electric panel, you should check the first box of flap. Typically, a fault be discovered. If it does not do voltage, hence, on the road is broken (which rarely happens). Lack of lighting in a room can be caused by a malfunction of the fixture (chandelier lamp) or a switch.

With control light or tester should be when the switch contact to verify the incoming voltage to the lighting fixture and switch. Most probably lies in these compounds. If the apartment is not working part of the socket, then stress in the Female group served, and the fault can be in non-performing outlets and a running outlet (power comes from it). Troubleshooting should start with a working outlet. Check the voltage on her way to first deal with two incoming wires, and then the two wires (phase and zero) of the outgoing wires. Contact between the wires can be oxidized and the electric current through that contact can not be held. Need to clean up the wires and re-tighten the contacts in the socket.